Kayayyaki
6300A Air Circuit Breaker
  • 6300A Air Circuit Breaker6300A Air Circuit Breaker
  • 6300A Air Circuit Breaker6300A Air Circuit Breaker

6300A Air Circuit Breaker

Model:DAA-6300
Zaɓi CDADA a matsayin mai siyar ku, 6300A Air Circuit Breaker shine babban zaɓi don samar da yawa, ƙungiyar IEC/GB ƙwararriyar babban ƙarfin da aka gina don tsire-tsire masu ƙarfi da amfani da masana'antu masu nauyi. Ya zo a cikin zane-zane da ƙayyadaddun nau'ikan, gyare-gyare don ingantaccen ingantaccen ƙarfin wutan lantarki. Mu ƙwararrun masana'anta ne, masu maraba da ayyukan OEM da yawancin odar ACB don masu siyan masana'antu na duniya.

Wannan CDADA 6300A Air Circuit Breaker cikakke ne don siye da yawa, an gina shi don mahimman abubuwan more rayuwa tare da AC 50Hz, dacewa 690V da kewayon 4000A-6300A na yanzu. Wannan ACB (samfurin 4P) yana ba da kariyar zaɓaɓɓen fasaha, manufa don tsire-tsire masu ƙarfi, ma'adinai da manyan wuraren masana'antu. Yana goyan bayan Nisa huɗu ta hanyar buɗe ido, yana haɗawa tare da SCADA da grids mai wayo, kuma yana aiki azaman abin dogaro mai keɓancewa ba tare da mai sarrafawa ba.


Sigar Samfura

Jerin Samfura: DA-6300
Tsari wanda aka ƙima a halin yanzu (Inm): 6300A
Ƙimar Yanzu (Ciki): 4000A/5000A/6300A
Sanduna: 4P misali (akwai 3P na al'ada)
Ƙimar Wutar Lantarki (Ue): 400V / 690V
Ƙarfafa Juriyar Wutar Lantarki: 8000V @ tsayin mita 2000 (≤12000V max)
Icu (400V/690V): 120kA/80kA
n × Icu (400V/690V): 264kA/0.2/187kA/0.2
Ics (400V/690V): 80kA/70kA
Icw (1s): 85kA / 100kA (MCR) @ 400V; 65kA / 75kA (MCR) @ 690V
Haɗin Waje (6300A): 120×10 mm jan karfe mashaya × 6 inji mai kwakwalwa da sandar sanda
Matsayi: GB14048.2, IEC60947-2

6300A Air Circuit Breaker6300A Air Circuit Breaker

Siffar Samfurin Da Aikace-aikace

CDADA 6300A ACB don aikace-aikacen shukar wutar lantarki an gina shi don matsananciyar dogaro a ƙarƙashin yanayin cikakken kaya. Ƙarfafa tsarin tuntuɓar sa da ɗimbin ɗaki arc chute yana ba da damar katsewa mai aminci a matakan kuskuren 120kA-mahimmanci don sauya kayan aiki mai amfani. Akwai a cikin duka 6300A drawout air circuit breaker da kafaffen jeri na ACB, yana goyan bayan gyare-gyare cikin sauri ba tare da rage kuzarin bas ɗin gaba ɗaya ba.


Me yasa injiniyoyi suka ƙayyade CDADA 6300A:

★ Ƙarfin ƙwanƙwasa mafi girma a cikin layin CDADA's low-voltage ACB

★ Inganta thermal zane don ci gaba da 6300A aiki

★ Pre-engineered karfinsu tare da manyan switchgear OEMs

★ Zaɓaɓɓen mai sarrafawa mai hankali tare da kariya ta yadudduka


Cikakken Bayani

A matsayin babban mai kera mai keɓan iska na 6300A, SHANGHAI DADA ELECTRIC yana amfani da madaidaicin simintin gyare-gyare da mashin ɗin CNC don tabbatar da daidaiton girman firam da hannun hannu. Kowane rukunin yana jurewa:

★ Gwajin hawan zafin jiki mai cikakken lodi (≤55K a 6300A)

★ Tabbatar da gajeriyar zagayowar 3 a Icu

Tabbatar da ka'idar sadarwa (Modbus/Profibus na zaɓi)


Banbancin Gasa:

★ 6-Layer azurfa-plated lamba surface for low juriya

★ Modular controller bay don ingantawa nan gaba

★ Fitarwa marufi tare da IP54-rated m murfin


Fa'idodin Kamfanin CDADA:

● Ƙwarewar OEM & ODM: 42 + shekaru;

● Fitowa na shekara: 3,000,000 masu rarrabawa;

● Girman masana'anta: 50,000 m2;

● Babban Injin Gudanarwa: Saiti 100;

● Injin Binciken Inganci: 50 sets;

● Ma'aikatanmu: 400 ma'aikata;

● Injiniyoyi na fasaha: ma'aikata 32;

● Mun tabbatar da samfurin mu a cikin manyan kungiyoyin masana na duniya

Muna ci gaba da tuntuɓar mu don magance kowace matsala yadda ya kamata

6300A Air Circuit Breaker

FAQ

Q1: Menene mafi girman ƙimar halin yanzu da ake samu don jerin CDADA 6300A?

A1: Jerin CDADA 6300A yana goyan bayan kimar igiyoyin ruwa har zuwa 6300A, tare da zaɓuɓɓukan matsakaici a 4000A da 5000A.


Q2: Shin 6300A Air Circuit Breaker ya dace da manyan masu shiga wutar lantarki?

A2: Ee - an ƙera shi musamman don tashar wutar lantarki, tashar wutar lantarki, da babban rarraba masana'antu, tare da Icu har zuwa 120kA a 400V.


Q3: Nawa ne sanduna tagulla ake buƙata ta kowane sanda don ƙirar 6300A?

A3: Don 6300A, kuna buƙatar guda shida (6) na sandunan tagulla na 120 × 10 mm kowane sanda don tabbatar da ɗaukar nauyi na yanzu da ƙarancin zafin jiki.


Q4: Shin wannan mai karyawa zai iya yin aiki ba tare da mai kulawa ba?

A4: Ee — naúrar tushe tana aiki azaman mai keɓewar hannu lokacin da ba a shigar da mai sarrafawa ba, kodayake kariya ta hankali tana buƙatar tsarin zaɓin mai sarrafawa.


Q5: Shin CDADA tana ba da saitunan sandar sanda na al'ada (misali, 3P maimakon 4P)?

A5: Lallai. Yayin da 4P daidai yake don aikace-aikacen ƙasa-ƙasa, ana samun nau'ikan 3P akan buƙatar takamaiman ƙirar tsarin.

Zafafan Tags: 6300A Air Circuit Breaker, China, Manufacturer, Maroki, Factory
Aika tambaya
Bayanan Tuntuɓi

Buɗe Maganin Lantarki na Al'ada a cikin Sa'o'i 24!

Me yasa ake tambaya tare da Babban Maƙerin Sinanci?

✅ Farashin Kamfanin Kai tsaye

Yanke kudin tsakiya! A matsayin masana'anta da aka tabbatar da ISO 9001 a China, muna isar da manyan MCCBs, MCBs, da masu fasa hasken rana DC a farashi masu fa'ida-wanda ke goyan bayan CE, KEMA, da takaddun ASTA.

✅ Shekaru 40+ na Kwarewar OEM/ODM

Gyara casings, lambobi, ko ƙayyadaddun bayanai na fasaha ba tare da wahala ba. Ƙungiyar R&D ɗin mu (hanyoyi 60+) suna amfani da su:

Ƙimar ƙarfin lantarki / ƙimar halin yanzu

Marufi mai alama

Saurin samfur (samfurori a cikin kwanaki 7)

✅ Iyawar Raka'a Miliyan 3+ Na Shekara

Babu oda mai girma ko gaggawa! Mu 52,400㎡ garanti na shuka:

◆ Lokacin jagora na kwanaki 15 don oda mai yawa

◆ MOQs masu sassauƙa

◆ Ƙuntataccen gwajin ASTM/UL

✅ Yarda da Duniya, Rashin Haƙuri

Muna warware shingen fitarwa na ƙasashe 45+:

Takaddun RoHS/REACH

Takamaiman takaddun shaida na yanki

Solar DC breakers don ayyukan kore na EU

X
Muna amfani da kukis don ba ku ingantaccen ƙwarewar bincike, bincika zirga-zirgar rukunin yanar gizo da keɓance abun ciki. Ta amfani da wannan rukunin yanar gizon, kun yarda da amfaninmu na kukis.takardar kebantawa
ƘiKarba